site stats

Sundance spa maxxus heater not working

WebSundance Spas does not offer just the elements, housings or O-rings. The High Limit Sensor 6600-168 that is plugged into the bottom of the heater housing is a bullet sensor that slides into a drywell. It may be held on by silicon and is removable to be used with the new heater. Related Products On Sale! Sundance®/Jacuzzi® WebSep 13, 2016 · FLOW SWITCH (heater is deactivated pump may also be deactivated) proper flow of water is inhibited or a flow switch has malfunctioned. Check for proper water level, and check for clogged stage 2 filter. FLO2- CLOSED OR SHORTED FLOW SWITCH ON SYSTEM START-UP (system disabled) flow switch is non-functional.

Maxxus™ Sundance® Spas - National Pools And Spas

WebCameo® – 880™ Series. The Cameo® spa seats up to six adults, offering the perfect variety of seat heights formed to fit diverse body types. Our best-selling lounge model, this spa has the best of everything, from illuminated grab bars to air-only aromatherapy-releasing jets. $$$$ Unlock Pricing. WebNov 23, 2024 · 756 99K views 3 years ago If your Jacuzzi or Sundance, or Sweetwater hot tub is displaying "-----" "OH" or an unusually high water temperature, a defective temperature sensor … brainstorming activities workplace https://felixpitre.com

Jacuzzi Sundance Hot Tub temperature sensor error repair

WebDamage caused by exposing the hot tub to this abuse is not covered by warranty. We recommend that you always keep the hot tub full of water when it is exposed to direct sunlight and that you keep the Sundance insulating cover in place at all times when the hot tub is not in use. WebMaxxus™ Overview The Maxxus™ spa has room for up to six adults and is our largest spa with a full-body lounge seat for total relaxation. This 880™ Series spa has the best of everything, from series-exclusive illuminated grab bars to patented Fluidix ® jets. WebIt can be fixed by submersing the heating element in vinegar water or any anti-clog substance. You can get a heating element replacement here. It happens abruptly when your heating element is cracked internally, which will disrupt the proper flow of electricity. Your tub will still heat up but not past 90-95 degrees. brainstorming advertising

Sundance Optima 850 with a FLO/FLO2 messages - Trouble Free Pool

Category:MOST COMMON SPA HEATER PROBLEMS AND TROUBLESHOOTING T…

Tags:Sundance spa maxxus heater not working

Sundance spa maxxus heater not working

MOST COMMON SPA HEATER PROBLEMS AND TROUBLESHOOTING TIPS

WebHeater is deactivated. Proper water flow is inhibited or flow/pressure switch may be obstructed, misaligned, or defective. Troubleshooting Steps: 1. Remove filter and allow air to bleed out of filter. Check filter for trapped air. 2. Check for proper water level. 3. Check for … Flow and Pressure Switches used on all of Sundance, Sweetwater, Del Sol and Su… WebTo gain access to the hot tub’s power terminal block, remove the screws securing the center cabinet panel (Maxxus™ and Aspen® models only) or the Quick Release buttons (except Maxxus and Aspen models) on the side of the hot tub under the controls.

Sundance spa maxxus heater not working

Did you know?

WebJul 22, 2015 · If this isn't the case, the heater will not operate. If you need help calibrating your pressure switch, you can call free hot tub support at Spadepot 800-823-3638. They can walk you through the process. Once you've established the pressure switch is operating … WebNov 23, 2015 · Is this pump running in line with the heater? If so it will be the pump to circulate water through the heater when the spa is asking for heat, which may be the cause of your error code. If that's the case, you will need to replace that pump to resolve the issue. I have no experience with your model of spa, but hope this info may help Quote

WebImportant Hot Tub Owner Information Your Sundance hot tub is constructed to the highest stan-dards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the hot tub for efficient operation, an … WebMost Sundance spas must be connected to 240V electrical service, but some offer the option of operating on either 120V or 240V. While connecting to 120V can be less involved, most customers prefer the benefits of the 240V spa, which include quicker heating time …

WebFeb 14, 2024 · TOP 5 SPA HEATER ISSUES AND FIXES “My spa isn’t heating!” This is one of the most common complaints of spa owners. Below is a list of possible causes for spa not heating. A spa heater that has stopped working could have issues with the spa heater …

WebDec 30, 2024 · MissionMan1. We have a 2001 Sundance 880 Maxxus. It has 3 pumps. One day out of the blue Pump #2 stopped working. I can hear the relay click but that is it. I have changed out the motherboard- not the issue- works exactly the same. Changed out the pumps for brand new ones- once again Pump 1 (two speed) and Pump 3 (single speed) is …

WebJun 8, 2024 · Worked fine. 2.) Disconnect the low wire from the circuit board and run just high speed. Worked fine, the relay cycled to the second speed just fine. 3.) Disconnect the high wire at both ends and substitute it with another wire that isn't in the harness to verify there isn't a short inside the harness. haddock street bootle liverpoolWebFeb 5, 2024 · Fix a Flow Sensor Error on Your Hot Tub and Fix Your Spa Not Heating How To The Spa & Sauna Company 2.16K subscribers Subscribe 158K views 3 years ago Request service … haddock st germain recipeWebWarranty Coverage. 10 Years Shell Structure – Sundance ® spas are warranted against water loss due to defects in the spa shell for ten years from the original date of purchase. 880™, 780™, and Select Series ®. 7 Years Shell Surface – Sundance ® spas are warranted against blistering, cracking or delaminated of the interior surface of ... brainstorming airplane for saleWebStep up to the Maxxus™ Spa. 90" x 110" x 41.5". Seats 6 Adults. Lounge Seating. 65 Total Jets. Volume: 540 gallons. Filled Weight: 6898 lbs. Dry Weight: 1143 lbs. CLEARRAY® Active Oxygen™ Clean Water System. brainstorming adviceWebThe Maxxus™ spa has room for up to six adults and is our largest spa with a full-body lounge seat for total relaxation. This 880™ Series spa has the best of everything, from series-exclusive illuminated grab bars to patented Fluidix ® jets. Throughout this Maxxus™ spa model, you’ll also find stunning SunSide cabinetry with integrated exterior corner … brainstorming activityWebNov 7, 2013 · 2007 Sundance Maxxus issue. Thread starter mrfritz815; Start date Nov 3, 2013; ... If your second pump is not working your waterfall and heater would not work. Your tub would not have enough flo to make them operational. ... Sundance Spa heater relay not working. dannyboy1; Dec 29, 2024; Spas and Hot Tubs; Replies 7 Views 175. haddockston houseWebMake Your Backyard Oasis. Shop All Hot Tubs. Pre-Delivery Guide. (2024) 980™ Series Manual - (Kingston™, Claremont®) (2024) 880™ Series Manual - (Aspen®, Maxxus®, Optima®, Cameo®, Altamar®, Marin®, Capri®) (2024) 780™ Series Manual - (Chelsee®, … haddock stew recipe